Industrial Raspberry Pi MICA-R4 Test Data

In on-site environments where IIoT is required, computer equipment is also expected to be placed under harsh conditions. A wide operating temperature range, excellent resistance to vibration and shock, and EMC performance are required to support such usage. This page introduces data from temperature tests, vibration/shock tests, and EMC tests of HARTING Industrial Raspberry Pi MICA-R4.

Temperature Test

Cold-boot test at -40°C and temperature cycling test were conducted using a thermostatic chamber. Operates even at 100% CPU load in a high temperature 90°C environment. MICA-R4 can be used in harsh temperature environments.

・Cold boot test at -40℃
・Temperature cycling test IEC 60068-2-14:09 Test Nb
 parameter:-40℃~+90℃
 Hold time:3h
 Cycle:5

(The temperature range for specifications is -20°C to +60°C. Highーtemperatu environments will shorten product life)

Temperature Cycling Test Graph
Node-RED screen at 100% CPU load

Vibration Shock Test

Vibration

IEC 60068-2-6:07 Test Fc Sinus
IEC 60721-3-3: Class 3M4
Frequency: 5 Hz – 8.5 Hz, Width p-p20㎜
Frequency: 8.5 Hz– 500 Hz Acceleration 3g

Shock

IEC 60068-2-27:10 Test Ea
IEC 60721-3-3: Class 3M6 & 3M7
Shock type: Half-sine
Acceleration:25g Duration: 6 ms
Number: 100 shocks (±)per axis(X, Y, Z)

EMC Test

Immunity tests :
EN IEC 61000-6-2:2019

Test Basic EMC standard or test method

for indutrial use
[] is result

for consumer use(referene)
[] is result

Electrostatic Discharge Test

EN 61000-4-2:2009

Contact ±4kV[B]
Air ±8kV[B]

Contact ±4kV[B]
Air ±8kV[B]

Radiated RF Electromagnetic Field Immunity Test

EN IEC 61000-4-3:2020

10V/m[A]

3V/m[A]

Electrical Fast Transient / Burst Test

EN 61000-4-4:2012

I/O: ±1kV[B]

I/O: ±0.5kV[B]

Surge immunity Test

EN 61000-4-5:2014+A1:2017

I/O: 0.5kV,1kV[B]

I/O: 0.5kV,1kV[B]

Conducted RF Immunity Test

EN 61000-4-6:2014

I/O:10V[A]

I/O:3V[A]

Power frequency magnetic field immunity

EN 61000-4-8:2010

30A/m[A]

3A/m[A]

Voltage fluctuation Test(AC)

EN IEC 61000-4-11:2020

N/A

N/A


Emission measurements:
EN IEC 61000-6-4:2019

Test Basic EMC standard or test method

for industrial use

for consumer use(reference)

Radiated emission
(enclosure port)

EN IEC 61000-6-4:2019 Table 3
EN 55016-2-3:2017+A1:2019

QP[10m]
30230MHz 40dB
2301000MHz 47dB

QP[3m]
13GHz 76dB
36GHz 80dB

QP[10m]
30~230MHz 30dB
230~1000MHz 37dB

QP[3m]
1~3GHz 70dB
3~6GHz 74dB

Conducted emissioin
(wired network port)

EN IEC 610006 4:2019 Table 5
EN 55032:2015+A11:2020+A1:2020

0.150.5MHz 79dB
0.55MHz 73dB
530MHz 73dB

0.15~0.5MHz 66-56dB
0.5~5MHz 56dB
5~30MHz 60dB